What's Happening

The inlet (drum) thermistor that monitors air entering the drum has failed. Without it, the dryer can't regulate heating properly.

How to Fix It

Unplug and test with a multimeter. Replace if readings are out of range. Check wiring harness for damage.

Frequently Asked Questions
What does F3E1 mean on a Maytag dryer?
F3E1 means the inlet thermistor has failed. This sensor monitors air temperature entering the drum.
What's the difference between F3E1 and F3E3?
F3E1 is the inlet (entering) thermistor. F3E3 is the exhaust (leaving) thermistor. Different sensors in different locations.
Can I replace it myself?
Yes, if you're comfortable with basic tools. The thermistor is accessible on most models and costs $10–$25.